Abstract
Spun prestressed concrete poles are commonly placed in severe marine or industrial environments that are conducive to corrosion of the steel reinforcement. Nonmetallic fiber-reinforced-polymer (FRP) materials have been considered as alternatives to steel reinforcement because of their mechanical properties, durability, and corrosion resistance.
This paper compares the flexural behavior of spun concrete poles reinforced with three types of reinforcement: carbonfiber-polymer, glass-fiber-polymer, and conventional prestressing steel reinforcement. The flexural behavior of the poles was evaluated in terms of cracking moment, ultimate moment capacity, and load-deflection data. A cost comparison was also performed. The results show that the different types of reinforcement are not associated with significant differences in the ultimate capacities of the poles but are correlated with differences in cracking and deflection.
References
Benmokrane, B., O. Chaallal, and R. Masmoudi. 1996. “Flexural Response of Concrete Beams Reinforced with FRP Reinforcing Bars.” ACI Structural Journal 93 (1): 46–55.
Theriault, M., and B. Benmokrane. 1998. “Effects of FRP Reinforcement Ratio and Concrete Strength on Flexural Behavior of Concrete Beams.” ASCE Journal of Composites for Construction 2 (1): 7–16.
Toutanji, H. A., and M. Saafi. 2000. “Flexural Behavior of Concrete Beams Reinforced with Glass Fiber-Reinforced Polymer (GFRP) Bars.” ACI Structural Journal 97 (5): 712–719.
Lyons, P. J. 2003. “Feasibility Study of CFRP Prestressed Spun Cast Concrete Poles for Transmission Line Support.” MS thesis, Department of Civil, Construction, and Environmental Engineering, University of Alabama, Tuscaloosa, AL.
Yost, J. R., S. P. Gross, and D. W. Dinehart. 2003. “Effective Moment of Inertia for Glass Fiber-Reinforced Polymer Reinforced Concrete Beams.” ACI Structural Journal 100 (6): 732–739.
Mota, C., S. Alminar, and D. Svecova. 2006. “Critical Review of Deflection Formulas for FRP-RC Members.” Journal of Composites for Construction 10 (3): 183–194.
Bischoff, P. H., and A. Scanlon. 2007. “Effective Moment of Inertia for Calculating Deflections of Concrete Members Containing Steel Reinforcement and Fiber-Reinforced Polymer Reinforcement.” ACI Structural Journal 104 (1): 68–75.
Shalaby, A. M., F. H. Fouad, and R. Albanese. 2011. “Strength and Deflection Behavior of Spun Concrete Poles with CFRP Reinforcement.” PCI Journal 56 (2): 55–77.
Terrasi, G. P., and J. M. Lees. 2003. “CFRP Prestressed Concrete Lighting Columns.” In Field Applicationsof FRP Reinforcement: Case Studies, 55–74. Farmington Hills, MI: ACI (American Concrete Institute).
ASTM Subcommittee A01.05. 2007. Standard Specification for Steel Wire, Plain, for Concrete Reinforcement. ASTM A82/A82M-07. West Conshohocken, PA: ASTM International.
PCI Committee on Prestressed Concrete Poles. 1997. “Guide for the Design of Prestressed Concrete Poles.” PCI Journal 42 (6): 94–134.